Mcquay model number tonnage.

Find Us. McQuay Air-conditioning Limited (+852) 2893 6261; Unit 901~905, 9/F,Elite Centre, 22 Hung To Road, Kwun Tong, Kowloon,Hong Kong

Mcquay model number tonnage. Things To Know About Mcquay model number tonnage.

The 30HXC units are freshwater- or seawater-cooled chillers, designed from the ground up to meet the needs of today and tomorrow: Non-ozone depleting HFC-134a refrigerant. Screw compressors. Fits through narrow access doors without disassembly. Mechanically cleanable evaporators and condensers. Wide range of marine & offshore customizations.Model MPS. Maverick® I packaged rooftop systems, from 3 to 25 tons, are designed from the ground up to include the features and benefits that are ideal for offices, schools, libraries, and strip malls. They combine the lower installation costs and interior space savings of a roof-mounted system with the operating and maintenance efficiencies ...All McQuay low and medium pressure central station air handling units (sizes 114 through 172) have factory installed, internally mounted motors and drives .. This means that ex­ pensive jobsite coordination and field mounting of motors has been eliminated .. Motor life is increased with the McQuay air handling unitsThe cooling and gas heating units with bottom duct connections, model EPGDA, are available in four cooling capacities: 2, 3, 4 and·5 tons. In ad­ dition, the EPGDA units are available with a 1 horsepower belt drive supply fan/motor assembly for higher static pressure applications on 3, 4 and 5 ton, 3-phase units.Look for two numbers in a cluster in the middle of the model number. They are divisible by 6 or 12, and represent the nominal BTU of the system in thousands. A ton of air conditioning equals 12,000 BTU, and 24 divided by 12 equals 2, so the data plate below indicates the system is 2 tons. Another example is TZPL4422B, which is 3.5 tons. Here ...

Overview. Positive pressure design with R-134a refrigerant which has no ozone depletion potential and no phase- out schedule. Smallest footprint per ton in the industry to optimize equipment room space. The exclusive movable diffuser geometry design avoids the potential for a surge. Quiet compressor design with unique refrigerant injection ...McQuay International Re-Manufactured Screw Compressor. Model: SAL155QA10DA. Capacity: 60 tons using Freon, only. ... 60 Ton. Sold Out. Roll over image to Zoom OR Click for full Gallery (images, video, data sheets) ... McQuay; Model: SAL155QA10DA; Serial Number: 55GR7061-10; Package Details. Screw Compressor Details. Micro Panel Details.

6 McQuay Cat 565-1 Introduction IntroductionQuality McQuay air handling equipment has been respected and regarded as high quality for nearly 60 years. McQuay has taken a major step in redefining the indoor air handler with the Vision air handler. Demands for improved indoor air quality, low sound, high operating efficiency and smaller mechanical Browse Model Number DX16SA0371, 16 SEER AC UNITARY 3 TON SINGLE STAGE in the Daikin North America LLC catalog including Model Number,Item Name,Description,Nominal Cooling Capacity,Sound Level,Compressor - Rated Load Amps,Compressor - Locked Rotor Amp

4 Port, 3-Ton Outdoor Heat Pump Efficiency SEER EER HSPF COP Non-Ducted 21.7 12.5 11.2 4.26 Ducted 16.9 11.0 9.1 3.5 Mixed 19.3 11.75 10.15 3.88 Electrical ... Included Part Number Description KEH082A41 Drain Pan Heater KPW082A41 Air Adjustment Grille KKG082A41 Back protection wire netThe Trane model number is #TWE030C140B0, let's try to decode this model number: TW = split component heat pump compatable. E = Electric furnace (like they said, heat strips are added in the field, could be anything from 10kw to 25 kw) 0 = Brazed refrigeration connection. 30 = 2.5 ton like you mentioned.Page 11: Changed Part Number note to "These Parts are ordered per Code Item on original G.O. Contact McQuay Parts with model and serial number information" Page 12: Added . LSB Motor Location Diagram. section. Page 15: Changed footnote #1 to "Obsolete and no longer available. Contact McQuay Parts for more information." Page 21, 22: AddedCommercial water source heat pumps can be applied to geothermal closed-circuit or open-well loops, or on a traditional boiler/tower loop system. These systems offer benefits ranging from low cost installation to the highest energy efficiency available in the market today. SmartSource® DOAS WSHP. 600 to 4,000 CFM. Product Info.McQuay has a great name in the air conditioner manufacturing industry. To maintain their reputation and provide customers with high-end products, they have a. ... Look at the label of both units and ensure that they are of the same model and size by matching part codes. If still getting the error, contact a technician to check the power supply ...

Daikin Applied RoofPak® RPS (15-140 Tons) Design flexibility, energy efficiency, system performance and reliability make Daikin RoofPak® applied rooftop systems the ideal solution for your one to eight-story building projects. Available in air-cooled and evaporative-cooled models, with capacities from 15 to 150 tons, they combine the lower ...

16" × 44" Flat Top Replacement Unit - Model PDAE/PDHE Unit Sizes 007 - 017 • R-410A Refrigerant ... In 2008 McQuay is proud to continue our tradition of design excellence with the introduction of our highly efficient and quiet 16 × 44 Applied PTAC/ PTHP. Type EA (1970)

*The McQUAY Group HI-F fin surface is covered by U.S. Patent Number 3,645,330. ©1975McQUAY Group, McQUAY-PERFEX INC. ... Available in three model types Low installation and operating costs. Plenum fans allow quieter operation. Modular construction from 20 to 130 tons. Controls flexibility—MicroTech® III controls for easy integration with the BAS of your choice. R-410A refrigerant allows higher efficiency (model SWP only) A self-contained AC unit from Daikin is an ideal option for multi ...You can determine the size in tons of your Tempstar HVAC system by examining the model number on the data plate at the side of the condenser (outdoor unit). Look for two numbers in the middle of the model number that are divisible by 6 or 12, and represent the nominal BTU of the system in thousands. A ton of air conditioning equals 12,000 BTU ...The tonnage of an AC unit can typically be determined from the model number by looking for a number that is divisible by 12. For example, if the model number is ABC12345, and the number 36 appears in the middle of the model number (e.g., ABC36 12345), then the AC unit is likely a 3-ton unit, since 36 is divisible by 12.Additional Product Details. McQuay & Snyder. McQuay Air Cooled Water Chiller- 220 Ton. Model ALS220A, S/N 56K8146201. (2) Compressors. Refrigerant: R 22. Overall dimensions: 356 in. L x 84 in. W x 95 in. H.

As with many other McQuay International chiller products, the Magnitude® model WMC meets all necessary certifications and standards. AHRI Certification Part load performance can be presented in terms of Integrated Part Load Value (IPLV), which is defined by AHRI Standard 550/590. Based on AHRI Standard 550/590, and as shownMcQuay Skyline OAH 021 Installation And Maintenance Manual (28 pages) Outdoor air handler Sizes 003 - 055. Brand: McQuay | Category: Air Handlers | Size: 1.3 MB.The PFH series are equipped with two compressors operating in parallel on a single evaporator and<br />. condenser. Model PJH series are the equivalent double bundle heat recovery units.<br />. The chillers use refrigerant R-134a to reduce the size and weight of the package compared to negative<br />.Model Number Reference Guide. Challenger 3000 Self-Contained Air Conditioning System - Technical Data Manual ... McQuay Website. Air-Cooled Chillers. ALS - Air-Cooled Rotary Screw Chiller - 070A through 425A - Installation, Operation and Maintenance Manual - June 1999 ... 55 to 200 Ton - Installation, Operation, Maintenance - 2016.Flush the system water piping thoroughly before making connections to the unit evaporator. Install a 40-mesh strainer in the inlet pipe to the chiller. Design the water piping so the chilled water circulating pump discharges into the evaporator inlet. Connect the return water line to the evaporator inlet connection.HVAC USA - HVAC Wholesale Distributor - Siemens, Johnson Controls, and More

Model AGZ 026Bthrough AGZ 130B Two-Circuit Chiller (4-Fan Model Illustrated) Model AGZ 010A through AGZ 034A, Single Circuit Chiller Cover Pictures: The upper unit is a Model AGZ 034A, 34 ton chiller. The lower unit is a Model AGZ 130B, 130 ton chiller with the end protective guard removed in order to view the unit interior. “W” Shaped CoilUnit model number (including any dash numbers) and serial number must always be used when referring a problem to Lennox in regard to repair parts, literature, wiring diagrams, etc. Use of ... tonnage to the Btuh capacities found in model numbers. Old Nomenclature BTU = TONS BTU = TONS -14 = 1 ton -95 = 7½ tons -21 = 1½ tons -135 = 10 tons

The optional factory-installed insulation of cold surfaces includes the evaporator and non-connection water head, suction piping, compressor inlet, and motor housing. Insulation is UL recognized (File # E55475). It is 3/4" thick ABS/PVC flexible foam with a skin. The K factor is 0.28 at 75°F.Have a McQuay 50 ton A/C chiller condenser with 4 scroll compressors, #1 and #3 have a 3/8" tube with schrader on a tee between compressor oil sumps for oil equalizing. #2 and #4 the same. On start up #1 dumps all its oil into #3... then with in 5-8 minutes #3 dumps all its oil into #1... :grin2: I mean the oil sight glass goes empty and fast.Nomenclature. ACU Split System Air Conditioners. 1-1/2 to 5 ton. © 2004 McQuay International. IM-800. Installation and Maintenance Manual. IM-800. Group: Unitary. Part …Lot 163 at ESS Industrial Equipment Auction; Ends October 20 (NO RESERVE!!!) from ESS - RBI Equipment Sales & Surplus.York/Quantech – Johnson Controls. Our literature library of data sheets, manuals, & engineering specs is constantly growing. If you need finding product literature call us at 214-321-4200. consistent with the McQuay rooftop line. Expanded flexibility along with the availability of the state-of-the-art, MicroTech direct digital control (DDC) system on the RDS 800C and 802C makes the RDS unit the ideal selection in rooftop air handlers. Lower installation costs The McQuay RoofPak air handling unit arrives on the job site McQuay Enfinity™ water source heat pumps incorporate the best of our past and the best of what's new. Using feed-back from building owners, consulting engineers, contrac- ... Model CCH (Standard Range - 55°F to 110°F) Model CCW (Extended Range/Geothermal - 25°F to 110°F) Vertical (Floor) Water Source HeatThe label/tag has faded all I have on file is the model number and the serial number, make. Question Posted By Francisco the Building Engineer on May 3, 2011. Refer to the manufacturer's website for their HVAC nomenclature of the model number and serial numbers and how those numbers correspond to the tonnage and other technical data.

View and Download McQuay ALR 110F product manual online. Air-Cooled Reciprocating Water Chillers, 110 to 150 Tons, 380 to 525 kW, R-22, 60 Hertz. ALR 110F chiller pdf manual download. Also for: Alr 120f, Alr 140f, Alr 130f, Alr 135f, Alr 145f, Alr 150f.

TGZ 080A. Operation And Maintenance Manual. Show all McQuay Water Heater manuals. View & download of more than 2218 McQuay PDF user manuals, service manuals, operating guides. Air Conditioner, Chiller user manuals, operating guides & specifications.

Industry-LeadingTechnologies. To meet and exceed demanding building performance criteria, our rooftop systems integrate advanced HVAC technologies including: Variable speed inverter compressor. Variable speed heat pump. Direct-drive fans with variable speed ECM or VFD motors. Energy recovery wheel. Outdoor air monitor. Modulating hot gas …For more information on this item, please send us an email and we will be in contact shortly. SALES. [email protected]. 817-229-3171. 817-966-5350. 210-413-3333. This Used 160 Ton McQuay Air Cooled Chiller (Quantity Two Available) has been inspected and is located in our facility in Bridgeport, Tx. View specs, images, and secure your ...Supply McQuay, central air conditioning repair parts MT3022 inventory Numbers M332608311 control module,Refrigeration Fittings Manufacturers &Refrigeration Fittings Suppliers Directory - Find a Others Manufacturer and Supplier. ... McQuay . Model Number: MT3022. Place of Origin: USA. Packaging & Delivery. ... EPROM, pump frequency conversion ...Cover pictures: Upper unit: Model WSC 087, 500 ton single compressor chiller with factory-mounted starter Lower unit: Model WDC 126, 2000 ton, dual compressor chiller ... Application McQuay Model Cooling, most hours at full load < 1250 tons WSC - Single compressor chiller Cooling, most hours at full load >1250 tons WCC - Dual compressor ...Daikin McQuay Packaged System Nominal capacity 006 = 6 tons 007 = 7.5 tons 010 = 10 tons 012 = 12 tons Design vintage A = Vintage 1. Cooling efficiency. H = High (exceeds ASHRAE 90.1) Line voltage 2 = 208 volt power supply 3 = 230 volt power supply 4 = 460 volt power supply 5 = 575 volt power supply Heat medium Y = None (cooling only) G ...Compressor Stage 1. Cooling Capacity 56000. Family Comfort. Gas Stages 1-Stage. Nominal Seer 16. Refrigerant R410A. Tonnage 5. Voltage (Phase) 208/230 V 1-Phase. Air Flow Vertical.McQuay R-410A condensing units are available with EERs that exceed ASHRAE 90.1-2004. R-407C inevitably forces the unit to be significantly less efficient or more expensive, while R-410A reduces energy costs. R-410A refrigerant components are always evenly mixed, which is not true for R-407C.contact McQuay with the model and serial number, they can tell you. Reply . 09-06-2009, 11:34 PM #3. Tuly. View Profile View Forum Posts ... that compressor is made to cover a range of tonnage. that model number can have different gears in it and impellers. thats why you need to go to mcquay to see the design specs on it. or if you know who the ...HVAC Guide Specifications. Air-Cooled Liquid Chiller Nominal Size: 5 Tons. Multiaqua Model Number: MAC060-01 N. Part 1-General 1.01 System Description. Multiaqua air-cooled liquid chillers are designed using scroll compressors, low sound condenser fans and high efficiency pumps. 1.02 Quality Assurance.ManualsLib has more than 140 McQuay Air Handlers manuals . Click on an alphabet below to see the full list of models starting with that letter: I M R S V. Models . Document Type . I. IM 777-3. Installation And Maintenance Manual. M. MCW 1000 C. Instruction Manual. MCW 1000H. Instruction Manual. MCW 1200 C. Instruction Manual.Used 22 ton McQuay chiller, model ALR022C, air cooled, R22 refrigerant, 25 hp compressor, air cooled, 460 volt, serial# 5ZC8505602, built 1994. ... AccuChiller chiller, Model LP2R2504, serial number 10555010708, includes (2) Trane compressors, Model numbers CSHA100K0E00 and CSHA150K0E00, 10 HP and 15 HP, serial number 07134KD91A.

Ruby: 972-777-6574. Jamey: 214-755-8019. [email protected]. Our Location. Our main service facility is located in Dallas, Texas. We ship anywhere in the United States, Mexico, Canada, South America and Internationally. Surplus Group. 2121 Santa Anna Ave. Suite 100.The date of production/manufacture or age of Marley® HVAC equipment can be determined from the serial number located on the data plate. Parent Company: Marley - SPX. Example serial number styles/formats found: Style 1: AQ-10041433-A1 496M.HVAC USA - HVAC Wholesale Distributor - Siemens, Johnson Controls, and MoreFor Luxaire, you should look near the middle of the model number for a two-digit number divisible by 6 or 12, which represents the nominal BTU of the system in thousands. Here's two examples of Luxaire model numbers: AL3A0 24 F1A and EASE-F0 30 SA. A ton of air conditioning equals 12,000 BTU, and 24 divided by 12 equals 2, so the the first ...Instagram:https://instagram. joanns huleni received a netspend card in the mailhannaford to go damariscottakobe bryant death pics reddit The Skyline® air handling unit is designed to meet or exceed these demands. In addition to our patented construction, it features a durable, weathertight cabinet that promotes long life of your air handler. Skyline® also combats air contamination with micro-filtration, bacteria-defeating UV lights, mold-resistant drain pans, and anti ... power outage crystal lake ilsmith funeral home wadesboro obituaries Evaporator Model Number CE 063 J AY 18 R Motor HP (X10) Impeller Type: J or K Impeller Size:060= 6.0" 063= 6.3" Gear Ratio (see Gears table for list) Compressor Model Number Compressor Type: CE= Centrifugal Hermetic PE 200 Unit Model Number Unit Type: PE- a single compressor, hermetic centrifugal chiller. Nominal Tonnage Unit … coastal farm and ranch the dalles or McQuay FMS Series Installation & Maintenance Data (24 pages) Vertical Water Source Heat Pump & Cooling Only Units. Brand: McQuay | Category: Heat Pump | Size: 0.74 MB. Table of Contents. Table of Contents. 1. Model Nomenclature. 2. Transportation and Shortage.Daikin McQuay 300054300 BRISTOL COMPRESSOR H22J363ABCA / 770019202400 35600 BTU 208/230/60/1 POE Replaces: SAMSUNG DB95-00297B Replaces: CARRIER P032-3524 Replaces: BRISTOL H29B35UABCA, H25B35QABCA, H25B35QABCA Replaces: McQuay 802003444, 0001223304, 0001223304K, WB1008 3.0 Ton Compressor - 35,530 Btu - USES 45/370 Cap SOLD SEPARATELY (ORDER # 067291523) - 86 LRA - 14.4 RLA - Liquid 1/2 ...McQuay Air Cooled Water Chiller- 220 Ton. Model ALS220A, S/N 56K8146201. (2) Compressors. Refrigerant: R 22. Overall dimensions: 356 in. L x 84 in. W x 95 in. H.